Dell 错误代码(供参考) 我试过报E1410 却是坏阵列卡 杯具

来源:互联网 发布:iphone光绘软件 编辑:程序博客网 时间:2024/06/11 00:01

Dell 错误代码(供参考) 我试过报E1410 却是坏阵列卡 杯具

 (2011-06-07 12:46:04)
转载
标签: 

it

 
Dell的服务器太多,每次都得上dell的网站查找代码,索性直接粘贴过来

 

Cable and Board Presence - Message Code: "x1Axx"Message CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?E1A10PDBPwrCableHighPDB power cable to the planar is missing or bad and system will not power on.Failing device is reseated/replaced/repaired.YesPre-PostE1A11PCIRsrConfigHighPCI risers are not configured correctly; some invalid configurations prevent system power on.Failing device is reseated/replaced/repaired.YesPre-PostE1A12PCIRsrMissingHighOne or all of the PCI risers is missing. This prevents system power on.Failing device is reseated/replaced/repaired.YesPre-PostE1A14SAS Cable ALowSAS cable A is missing or bad.Failing device is reseated/replaced/repaired.YesAnyE1A15SAS Cable BLowSAS cable B is missing or bad.Failing device is reseated/replaced/repaired.YesAnyE1A16SAS Cable FBLowFlex bay SAS cable is missing or bad.Failing device is reseated/replaced/repaired.YesAnyE1A17PwrCable FBLowFlex bay power cable is missing or bad.Failing device is reseated/replaced/repaired.YesAnyE1A18PDBCtrl CableHighPDB control cable to the planar is missing or bad and system will not power on.Failing device is reseated/replaced/repaired.YesAnyTemperature - Message Code: "x11xx"Message CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?E1114Temp AmbientMedAmbient temperature has a reached a point outside of the allowed range.Temperature returns to allowable range.YesAnyE1116Temp MemoryHighMemory has exceeded allowable temperature and has been disabled to prevent damage to the components.AC Cycle or SEL clearYesAnyVoltages - Message Code: "x12xx"Message CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?E1210CMOSBattLowCMOS battery is missing or the voltage is outside of the allowable range.Failing device is reseated/replaced/repaired.YesAnyE1211ROMBBattLowPERC5I RAID battery charger has reported to the Server Management that the battery is either missing, can't charge the battery (possibly because of high temperatures), or the battery is bad.Failing device is reseated/replaced/repaired.YesAnyW1228ROMBBatt< 24 hrLowThis is a predictive failure warning message telling the user that the PERC5I RAID battery has less then 24 hours of charge left init. We provide this message as a warning message to the customer.Battery charges to > 24 hours of sustained charge.YesAnyE12141.5VPwrGdHigh1.5 VV voltage regulator has failed.AC Cycle or SEL clearYesAnyE12151.8VPwrGdHigh1.8 VV voltage regulator has failed.AC Cycle or SEL clearYesAnyE12163.3VPwrGdHigh3.3 V voltage regulator has failed.AC Cycle or SEL clearYesAnyE12175VPwrGdHigh5 V voltage regulator has failed.AC Cycle or SEL clearYesAnyE1218PCIRsr5VPwrGdHighPCI Riser 5 V voltage regulator has failed.AC Cycle or SEL clearYesAnyE1219BackplanePwrGdHighBackplane voltage regulator has failed.AC Cycle or SEL clearYesAnyE1221Flex BayPwrGdHighFlex Bay voltage regulator power good has failed.AC Cycle or SEL clearYesAnyE1222VCACHE #PwrGdHighVCACHE # voltage regulator has failed.AC Cycle or SEL clearYesAnyE1223VRM #PwrGdHighVRM # voltage regulator has failed.AC Cycle or SEL clearYesAnyE1225ESB 1.5VPwrGdHighESB 1.5 VV voltage regulator has failed.AC Cycle or SEL clearYesAnyE1226PCIRsr1.5VPwrGdHighPCI Riser 1.5 VV voltage regulator has failed.AC Cycle or SEL clearYesAnyE1227LinearPwrGdHighLinear voltage regulator(s) has failed. Represents status of multiple voltage regulators used in the video and LOM circuitry.AC Cycle or SEL clearYesAnyE12280.9VPwrGdHighMemory VTT voltage regulator has failed.AC Cycle or SEL clearYesAnyE1229CPU # VCOREHighProcessor # VCORE voltage regulator has failed.AC Cycle or SEL clearYesAnyE122ACPU VTTPwrGdHighProcessor VTT voltage regulator has failed.AC Cycle or SEL clearYesAnyE122B0.9 V Over VoltageHigh0.9 V regulator voltage has exceeded the allowable voltage range.AC Cycle or SEL clearYesAnyE122CCPU Power FaultHighA voltage regulator failure was detected when the processor regulator(s) was enabled.AC Cycle or SEL clearYesAnyFans - Message Code: "x13xx"Message CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?E1310RPM Fan ##LowRPM of fan ## is outside of the intended operating range.Fan RPM reading returns to a point inside of the intended operating range.YesAnyE1311RPM Fan Mod #ALowRPM of fan A in the # module is outside of the intended operating range.Fan RPM reading returns to a point inside of the intended operating range.YesAnyE1311RPM Fan Mod #BLowSame as above except for fan B of module #.Fan RPM reading returns to a point inside of the intended operating range.YesAnyE1311RPM Fan Mod #CLowSame as above except for fan C of module #.Fan RPM reading returns to a point inside of the intended operating range.YesAnyE1311RPM Fan Mod #DLowSame as above except for fan D of module #.Fan RPM reading returns to a point inside of the intended operating range.YesAnyE1313Fan RedundancyLowThe system is no longer fan redundant. Another fan failure would put the system at risk of over-heating.Fan redundancy is regained, which requires all fans to be operating within the intended operating range.YesAnyProcessors - Message Code: "x14xx"Message CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?E1410CPU # IERRHighProcessor # has had an internal error (IERR), but this does not always mean that CPU is the problem .There are a large variety of issues that cause an IERR.AC Cycle or SEL clearYesAnyE1414CPU #ThermtripHighProcessor # has encountered a Thermtrip(over-temperature) event.AC Cycle or SEL clearYesAnyE1418CPU # PresenceHighProcessor # is missing/bad and the system is in an unsupported configuration.AC Cycle or SEL clearYesPre-POSTE141CCPU MismatchHighProcessors are not compatible as defined by Dell .System is in an unsupported configuration.AC Cycle or SEL clearYesPre-POSTE141FCPU ProtocolHighBIOS has reported a processor protocol error.AC Cycle or SEL clearYesPOST, After POSTE1420CPU Bus PERRHighBIOS has reported a processor bus PERR (parity error).AC Cycle or SEL clearYesPOST, After POSTE1421CPU InitHighBIOS has reported a processor initialization error.AC Cycle or SEL clearYesPOST, After POSTE1422CPU MachineChkHighBIOS has reported a machine check error.AC Cycle or SEL clearYesPOST, After POSTSystem Memory - Message Code: "x21xx"Message CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?E2110MBECrdx DIMM ## & ##HighOne of the DIMMs in the set implicated by "## & ##" has had a multi-bit error (MBE).If no memory riser is present the “Crdx” string is left out of the message.“x” is the memory riser, A-Z.AC Cycle or SEL clearYesPOST, After POSTE2111SBE Log DisableCrdx DIMM ##HighBIOS has disabled memory single-bit error (SBE) logging and will not log anymore SBEE's until the system is rebooted.## represents DIMM implicated by BIOS .If no memory riser is present the “Crd x” string is left out of the message.“x” is the memory riser, A-Z.System resetYesPOST, After POSTE2112MemSpareCrdx DIMM ##HighBIOS has spared the memory because it has determined the memory had too many errors.## represents DIMM implicated by BIOS. If no memory riser is present the “Crdx” string is left out of the message.“x” is the memory riser, A-Z.System resetYesPOST, After POSTE2113Mem Mirror Crd x DIMM ## & ##HighBIOS has disabled memory mirroring because it has determined one half of the mirror has had too many errors. ## & ## represents DIMM pair implicated by BIOS. If no memory riser is present the “Crdx” string is left out of the message.“x” is the memory riser, A-Z.System resetYesPOST, After POSTI2114MemRaidLowBIOS Memory RAID BankUser action, sensor return to normalYesAnyI2115MemAdded Card xLowMemory has been added while the system is running.AC Cycle or SEL clearYesAnyI2116MemRemovedLowMemory has been removed while the system is running.AC Cycle or SEL clearYesAnyE2117MemHot PlugLowMemory hot-plug operation has failed.AC Cycle or SEL clearYesAnyE2118Fatal NBMemCRCHighNorthbound FBD CRC error on non-redundant entry. One of the connections in the FBD link on the Northbound (towards the MCH) side is "broken".This is determined by the MCH when two CRC errors have been detected twice in a row.AC Cycle or SEL clearYesPOST, After POSTE2119Fatal SBMemCRCHighFBD alert on non-redundant entry. One of the connections in the FBD link on the Southbound (towards the AMB'son the FBDIMM's) side is "broken".This is determined by the MCH when two CRC errors have been detected twice in a row.AC Cycle or SEL clearYesPOST, After POSTPower Supplies - Message Code: "x16xx"Message CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?E1610PS # MissingLowPower supply # was removed or is missing from the system.Failing device is reseated/replaced/repaired.YesAnyE1614PS # StatusLowPower supply # has failed.Failing device is reseated/replaced/repaired.YesAnyE1618PS # PredictiveLowPower supply # has a failure that predicts a power down event in this supply (i.e. power supply fan failure or power supply over-temp).Failing device is reseated/replaced/repaired.YesAnyE161CPS # Input LostLowPower supply # is attached to the system but has lost its AC/DC input.Failing device is reseated/replaced/repaired.YesAnyE1620PS #Input RangeLowPower supply #'s AC/DC input is outside of the allowable range.Failing device is reseated/replaced/repaired.YesAnyE1624PS RedundancyLowThe power supply subsystem is no longer redundant. If the last supply fails the system will go down.Failing device is reseated/replaced/repaired.YesAnyE1625PS AC CurrentLowThe power supply input power is above the allowed amount for the power supply.Failing device is reseated/replaced/repaired.YesAnyBIOS - Message Code: "x17xx"Message CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?E1710I/O ChannelChkHighBIOS has reported an I/O channel check.AC Cycle or SEL clearYesPOST, After POSTE1711PCI PERR B## D## F##HighBIOS has reported PCI parity error on a component that resides in PCI configuration space at bus ##, device ##, function ##.AC Cycle or SEL clearYesPOST, After POSTE1711PCI PERR Slot #HighBIOS has reported PCI parity error on a component that resides in slot #.Same as above.Same as above.Same as above.E1712PCI SERR B## D## F##HighBIOS has reported a PCI system error on a component that resides in PCI configuration space at bus ##, device ##, function ##.AC Cycle or SEL clearYesPOST, After POSTE1712PCI SERR Slot #HighBIOS has reported a PCI system error on a component that resides in slot #.Same as above.Same as above.Same as above.E1714Unknown ErrLowBIOS has determined there has been an error in the system but is unable to determine its origin.AC Cycle or SEL clearYesPOST, After POSTE171FPCIE Fatal Err B## D## F##HighBIOS has reported a PCIe fatal error on a component that resides in PCI configuration space at bus ##, device ##, function ##.AC Cycle or SEL clearYesPOST, After POSTE171FPCIE Fatal Slot #HighBIOS has reported a PCIe fatal error on a component that resides in slot #.Same as above.Same as above.Same as above.Hard Drives - Message Code: "x18xx"Message CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?E1810HDD ## FaultLowHard drive ## has had a fault as determined by the SAS subsystem.AC Cycle or SEL clearYesPOST, After POSTE1811HDD ##RbldAbrtLowDrive ## has had its rebuild aborted.AC Cycle or SEL clearYesPOST, After POSTE1812HDD ## RemovedLowDrive ## has been removed from the system.System reset or device is reseated/replaced/repaired.YesPOST, After POSTMiscellaneous- Message Code: "x19xx"Message CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?I1910IntrusionLowThe chassis lid has been removed.Chassis lid is returned to the system.YesAnyI1911>3ERRsChkLogN/AUser must check the system event log (SEL) for the rest of the errors on the system .Thee LCD is limited to three error, warning, and/or informational messages at a time based on priority level.Less than 3 events to display on the LCD.NoAnyI1912SEL FullMedSystem Event Log is full of events and because of this is unable to log anymore. You must clear the log in order for the Server Management controller to log any more events.AC Cycle or SEL clearYesAnyE1913CPU & Firmware MismatchMedCurrent version of BMC firmware is incompatible with the Woodcrest processor.AC Cycle or SEL clearYesPOSTBIOS Progress Codes - Message Code: N/AMessage CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?N/APOWERN/A0x01 -- System power-on.N/ANoAnyN/AMCODEN/A0x02 -- CPU Microcode load.N/ANoAnyN/ACINITN/A0x03 -- Chipset Initialization.N/ANoAnyN/AMEMCN/A0x04 -- Memory Configuration.N/ANoAnyN/ASBIOSN/A0x05 -- BIOS shadow into memory.N/ANoAnyN/APINITN/A0x06 -- Multiprocessor Initialization.N/ANoAnyN/ASTARTN/A0x07 -- POST processing start.N/ANoAnyN/ASMMN/A0x08 -- System management interrupt (SMI) initialization.N/ANoAnyN/APCIENN/A0x09 -- PCI Bus Enumeration & Video initialization.N/ANoAnyN/AVIDEON/A0x40 -- Display sign-on.N/ANoAnyN/APCICN/A0x41 -- PCI Configuration.N/ANoAnyN/AOSN/A0x7F -- Give control to OS.N/ANoAnyN/AE2010N/A0x80 -- No memory installed in the system.N/ANoAnyN/AE2011N/A0x81 -- Memory detected but is not configurable .Error detected during memory configuration. Could be result of bad memory, mismatched memory or bad socket.N/ANoAnyN/AE2012N/A0x82 -- Memory configured but not usable. Memory sub-system failure. Could be the result of bad memory.N/ANoAnyN/AE2013N/A0x83 -- BIOS failed to copy its flash image into memory. Could be the result of bad memory.N/ANoAnyN/AE2014N/A0x84 -- CMOS failure. CMOS'S RAM not working.N/ANoAnyN/AE1215N/A0x05 -- DMA controller failure.N/ANoAnyN/AE1116N/A0x80 -- Interrupt controller failure.N/ANoAnyN/AE1217N/A0x07 -- Timer refresh failure.N/ANoAnyN/AE1218N/A0x28 -- Programmable interval timer error.N/ANoAnyN/AE0119N/A0x29 -- Parity error.N/ANoAnyN/AE122AN/A0x2a -- SIO failure.N/ANoAnyN/AE122BN/A0x00b0 -- Keyboard controller failure.N/ANoAnyN/AE141CN/A0x3c -- System management interrupt (SMI) initialization failure.N/ANoAnyN/AE.11N/A0xC4 -- BIOS shutdown test failure.N/ANoAnyN/AE.11N/A0xC4 -- BIOS POST memory test failure. Could be the result of bad memory.N/ANoAnyN/AE141FN/A0xC4 -- Dell remote access controller (DRAC) configuration failure. Check screen for the actual error message.N/ANoAnyN/AE0000N/A0xC4 -- CPU configuration failure. Check screen for the actual error message.N/ANoAnyN/AE1221N/A0xC4 -- Incorrect memory configuration. Memory population order not correct. Refer to the user guide.N/ANoAnyN/AE1222N/A22x -- General failure after video. Check screen for the actual error message.N/ANoAnyBIOS Fatal Error Codes - Message Code: "x20xx"Message CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?E2010No MemoryHigh0x80 -- No memory installed in the system.System resetYesPOSTE2011MemConfigErrHigh0x81 -- Memory detected but is not configurable. Error detected during memory configuration. Could be result of bad memory, mismatched memory or bad socket.System resetYesPOSTE2012Unusable MemoryHigh0x82 -- Memory configured but not usable. Memory sub-system failure. Could be the result of bad memory.System resetYesPOSTE2013Shadow BIOS FailHigh0x83 -- BIOS failed to copy its flash image into memory. Could be the result of bad memory.System resetYesPOSTE2014CMOS FailHigh0x84 -- CMOS failure. CMOS'S RAM not working.System resetYesPOSTE2015DMA ControllerHigh0x85 -- DMA controller failure.System resetYesPOSTE2016IntControllerHigh0x86 -- Interrupt controller failure.System resetYesPOSTE2017Timer FailHigh0x87 -- Timer refresh failure.System resetYesPOSTE2018ProgTimerHigh0x88 -- Programmable interval timer error.System resetYesPOSTE2019Parity ErrorHigh0x89 -- Parity error.System resetYesPOSTE201ASIO ErrHigh0x8A -- SIO failure.System resetYesPOSTE201BKybdControllerHigh0x8B -- Keyboard controller failure.System resetYesPOSTE201CSMI InitHigh0x8C -- System management interrupt (SMI) initialization failure.System resetYesPOSTE201DShutdown TestHigh0xC0 -- BIOS shutdown test failure.System resetYesPOSTE201EPOSTMemTestHigh0xC1 -- BIOS POST memory test failure. Could be the result of bad memory.System resetYesPOSTE201FDRACConfigHigh0xC2 -- Dell remote access controller (DRAC) configuration failure. Check screen for the actual error message.System resetYesPOSTE2020CPUConfigHigh0xC3 -- CPU configuration failure. Check screen for the actual error message.System resetYesPOSTE2021Memory PopulationHigh0xC4 -- Incorrect memory configuration. Memory population order not correct. Refer to the user guide.System resetYesPOSTE2022POST FailHigh0xFE -- General failure after video. Check screen for the actual error message.System resetYesPOSTSpecial Exceptions - Message Code: "x10xx"Message CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?E1000Failsafe, Call SupportSpecialCheck System Event Log for critical failure details.AC Cycle or SEL clearYesAny